A Preliminary Study to Investigate the Correlation Between Position-Specific Effect of Interphase Gap and Competing Acoustic Environments Speech Recognition in Cochlear Implant Receivers
The Application of Auditory Evoked Potentials in Cochlear Implantation|更新时间:2026-07-30
|
A Preliminary Study to Investigate the Correlation Between Position-Specific Effect of Interphase Gap and Competing Acoustic Environments Speech Recognition in Cochlear Implant Receivers
Chinese Scientific Journal of Hearing and Speech RehabilitationVol. 24, Issue 1, Pages: 29-34(2026)
GONG Meng-fang,HE Qian,ZHU Xiao-ting,et al.A Preliminary Study to Investigate the Correlation Between Position-Specific Effect of Interphase Gap and Competing Acoustic Environments Speech Recognition in Cochlear Implant Receivers[J].Chinese Scientific Journal of Hearing and Speech Rehabilitation,2026,24(01):29-34.
GONG Meng-fang,HE Qian,ZHU Xiao-ting,et al.A Preliminary Study to Investigate the Correlation Between Position-Specific Effect of Interphase Gap and Competing Acoustic Environments Speech Recognition in Cochlear Implant Receivers[J].Chinese Scientific Journal of Hearing and Speech Rehabilitation,2026,24(01):29-34.DOI: 10.3969/j.issn.1672-4933.2026.01.006.
A Preliminary Study to Investigate the Correlation Between Position-Specific Effect of Interphase Gap and Competing Acoustic Environments Speech Recognition in Cochlear Implant Receivers
This study aimed to investigate the position-specific correlationbetween peripheral auditory nerve function (evaluated via the interphase gap effect
IPG effect) and speech recognition performance in competing acoustic environments among cochlear implant (CI) users
with a focus on the differential contributions of neural functions across cochlear regions.
Methods
2
Thirteen unilateral Nurotron CS-20A(TM) CI users (aged 9-68 years)
all with an implanted electrode length of 22 mm
were included
and the slopes of the amplitude growth functions (AGF) of the electrically evoked compound action potential (ECAP) were measured at four electrodes from the cochlea apex to the cochlea floor (E1:213 Hz
E7:945 Hz
E13:1920 Hz
and E19:3992 Hz) in the IPG = 5 μs versus 30 μs condition
and the electrode-specific IPG was calculated. Speech tests included correct bisyllabic word/phrase recognition in quiet vs. steady state noise (+5dB SNR)
and closed-set phrase recognition threshold (TMR) under competing masking of same-sex (male) vs. opposite-sex (female) voices.
Results
2
There were inter-individual and inter-electrode differences in the IPG effect (E1:18%
E7:51%
E13:56%
E19:28%; elicitation rates 61.5%-84.6%).The IPG effect in the E1 (low-frequency region) was positively correlated with disyllabic word recognition rate in quiet/noise (
r
=0.555-0.723
P
<
0.05)
and sentence recognition rate in noise (
r
=0.589
P
=0.034)
and negatively correlated with female voice masking recognition threshold (
r
=-0.637
P
=0.019).
Conclusion
2
There is a clear location-specific association between the IPG effect and speech recognition performance
and low-frequency neural function in the cochleo-parietal region (E1) is a key biomarker of speech perception in noisy and competing contexts.The IPG effect can be used as a specific indicator for assessing the health of peripheral nerves.
关键词
Keywords
references
Seyyedi M , Viana LM , Jr Nadol JB . Within-subject comparison of word recognition and spiral ganglion cell count in bilateral cochlear implant recipients [J ] . Otol Neurotol , 2014 , 35 ( 8 ): 1446 - 1450 .
Tao DD , Liu YW , Fei Y , et al . Effects of age and duration of deafness on Mandarin speech understanding in competing speech by normal-hearing and cochlear implant children [J ] . J Acoust Soc Am , 2018 , 144 ( 2 ): EL131 .
Holden LK , Finley CC , Firszt JB , et al . Factors affecting open-set word recognition in adults with cochlear implants [J ] . Ear Hear , 2013 , 34 ( 3 ): 342 - 360 .
Pfingst BE , Zhou N , Colesa DJ , et al . Importance of cochlear health for implant function [J ] . Hear Res , 2015 , 322 : 77 - 88 .
DeVries L , Scheperle R , Bierer JA . Assessing the Electrode-Neuron Interface with the Electrically Evoked Compound Action Potential, Electrode Position, and Behavioral Thresholds [J ] . J Assoc Res Otolaryngol , 2016 , 17 ( 3 ): 237 - 252 .
Kim JR , Abbas PJ , Brown CJ , et al . The relationship between electrically evoked compound action potential and speech perception: a study in cochlear implant users with short electrode array [J ] . Otol Neurotol , 2010 , 31 ( 7 ): 1041 - 1048 .
Prado-Guitierrez P , Fewster LM , Heasman JM , et al . Effect of interphase gap and pulse duration on electrically evoked potentials is correlated with auditory nerve survival [J ] . Hear Res , 2006 , 215 ( 1-2 ): 47 - 55 .
Hughes ML , Choi S , Glickman E . What can stimulus polarity and interphase gap tell us about auditory nerve function in cochlear-implant recipients? [J ] . Hear Res , 2018 , 359 : 50 - 63 .
Ramekers D , Versnel H , Strahl SB , et al . Auditory-nerve responses to varied inter-phase gap and phase duration of the electric pulse stimulus as predictors for neuronal degeneration [J ] . J Assoc Res Otolaryngol , 2014 , 15 ( 2 ): 187 - 202 .
Schvartz-Leyzac KC , Pfingst BE . Across-site patterns of electrically evoked compound action potential amplitude-growth functions in multichannel cochlear implant recipients and the effects of the interphase gap [J ] . Hear Res , 2016 , 341 : 50 - 65 .
Pfingst BE , Hughes AP , Colesa DJ , et al . Insertion trauma and recovery of function after cochlear implantation: Evidence from objective functional measures [J ] . Hear Res , 2015 , 330 ( Pt A ): 98 - 105 .
Schvartz-Leyzac KC , Pfingst BE . Assessing the Relationship Between the Electrically Evoked Compound Action Potential and Speech Recognition Abilities in Bilateral Cochlear Implant Recipients [J ] . Ear Hear , 2018 , 39 ( 2 ): 344 - 358 .
Zamaninezhad L , Mert B , Benav H , et al . Factors influencing the relationship between cochlear health measures and speech recognition in cochlear implant users [J ] . Front Integr Neurosci , 2023 , 17 : 1125712 .
Turner CW , Gantz BJ , Vidal C , et al . Speech recognition in noise for cochlear implant listeners: benefits of residual acoustic hearing [J ] . J Acoust Soc Am , 2004 , 115 ( 4 ): 1729 - 1735 .
Sargsyan G , Kanaan N , Lenarz T , et al . Comparison of speech recognition in cochlear implant patients with and without residual hearing: A review of indications [J ] . Cochlear Implants Int , 2021 , 22 ( 5 ): 257 - 264 .
He S , Xu L , Skidmore J , et al . The Effect of Interphase Gap on Neural Response of the Electrically Stimulated Cochlear Nerve in Children With Cochlear Nerve Deficiency and Children With Normal-Sized Cochlear Nerves [J ] . Ear Hear , 2020 , 41 ( 4 ): 918 - 934 .
Tao DD , Fan Y , 3rd Galvin JJ , et al . Effects of Masker Intelligibility and Talker Sex on Speech-in-Speech Recognition by Mandarin Speakers Across the Lifespan [J ] . Ear Hear , 2025 , 46 ( 4 ): 1085 - 1094 .
Tao DD , Fu QJ , 3rd Galvin JJ , et al . The development and validation of the Closed-set Mandarin Sentence (CMS) test [J ] . Speech Commun , 2017 , 92 : 125 - 131 .
Brungart DS , Simpson BD , Ericson MA , et al . Informational and energetic masking effects in the perception of multiple simultaneous talkers [J ] . J Acoust Soc Am , 2001 , 110 ( 5 Pt 1 ): 2527 - 2538 .
Fu QJ , Zhu M , Wang X . Development and validation of the Mandarin speech perception test [J ] . J Acoust Soc Am , 2011 , 129 ( 6 ): EL267 - 273 .
Schvartz-Leyzac KC , McClaskey CM , Dias JW , et al . Contributions of Auditory Nerve Density and Synchrony to Speech Understanding in Older Cochlear Implant Users [J ] . J Assoc Res Otolaryngol , 2025 , 26 ( 3 ): 317 - 329 .