1.解放军总医院耳鼻咽喉头颈外科医学部/国家耳鼻喉疾病临床研究中心 北京 100048
2.中国科学院大学 北京 100190
杨紫良 硕士;研究方向:咽喉嗓音疾病
黄冬雁,E-mail:huangdy301@163.com
收稿:2026-05-27,
修回:2026-08-25,
录用:2026-09-28,
纸质出版:2026-11-15
移动端阅览
杨紫良,祝国隽,张三国等.基于GRBAS-G维度标注与支持向量机的病理嗓音自动检测初步研究[J].中国听力语言康复科学杂志,2026,24(06):639-643.
YANG Zi-liang,ZHU Guo-juan,ZHANG San-guo,et al.Automatic Detection of Pathological Voice Using a Support Vector Machine Trained on GRBAS Grade (G) Ratings: A Preliminary Study[J].Chinese Scientific Journal of Hearing and Speech Rehabilitation,2026,24(06):639-643.
杨紫良,祝国隽,张三国等.基于GRBAS-G维度标注与支持向量机的病理嗓音自动检测初步研究[J].中国听力语言康复科学杂志,2026,24(06):639-643. DOI: 10.3969/j.issn.1672-4933.2026.06.014.
YANG Zi-liang,ZHU Guo-juan,ZHANG San-guo,et al.Automatic Detection of Pathological Voice Using a Support Vector Machine Trained on GRBAS Grade (G) Ratings: A Preliminary Study[J].Chinese Scientific Journal of Hearing and Speech Rehabilitation,2026,24(06):639-643. DOI: 10.3969/j.issn.1672-4933.2026.06.014.
目的
2
构建以听感知评估GRBAS量表总体音质(grade,G)维度评分为监督标签的病理嗓音自动检测模型,为病理性嗓音筛查及嗓音质量客观评估提供辅助工具。
方法
2
回顾性选取2020年1月至2022年3月解放军总医院第六医学中心病理嗓音数据库中662例语音样本,由5名专业听评人员完成标准化GRBAS听感知评估,采用Fleiss Kappa系数评价各GRBAS维度评估者间一致性,选取至少3名评估者G评分一致的443例样本构建建模数据集。以G0为正常嗓音组,G1~G3为病理嗓音组,提取梅尔频率倒谱系数(Mel-frequency cepstral coefficients,MFCC)及基于计盒维数(Db10)小波包分解的多频带非线性动力学特征,包括Hurst指数、2-Rényi熵和计盒维数Db,采用多项式核支持向量机(support vector machine,SVM)构建正常/病理嗓音二分类模型,通过分层十折交叉验证评估模型性能。
结果
2
G维度的Fleiss Kappa值为0.51,高于R、B、A、S维度的0.25~0.28。最优特征组合为MFCC+Hurst+2-Rényi+Db,模型平均准确率为84.4%,最高准确率为91.0%,敏感度为83.6%,特异度为85.1%,受试者工作特征曲线下面积(area under the receiver operating characteristic curve,AUC)为0.89,95%置信区间为0.86~0.92。
结论
2
融合线性频谱特征与多频带非线性动力学特征的机器学习模型可较好区分正常嗓音与病理嗓音。以GRBAS-G维度进行监督标注的病理嗓音自动检测具有可行性,可为临床嗓音异常的无创筛查与客观评估提供辅助工具。
Objective
2
To develop an automatic machine-learning model for pathological voice detection based on the G dimension of the GRBAS scale
providing an objective auxiliary tool for clinical voice assessment.
Methods
2
A total of 662 voice samples were retrospectively selected from a pathological voice database at a single center between January 2020 and March 2022. Five trained raters performed GRBAS auditory-perceptual assessments
and the interrater agreement of each GRBAS dimension was evaluated using the Fleiss kappa coefficient. A modeling dataset was constructed using 443 samples in which at least three raters agreed on the G score. G0 was defined as normal voice
whereas G1-G3 were defined as pathological voice. Mel-frequency cepstral coefficients (MFCC) and multi-band nonlinear dynamic features based on Db10 wavelet packet decomposition
including the Hurst exponent
2-Rényi entropy
and box-counting dimension Db
were extracted. A polynomial-kernel support vector machine (SVM) was developed for binary classification
and model performance was evaluated using stratified 10-fold cross-validation.
Results
2
The Fleiss' kappa of the G dimension was 0.51
higher than those of the R
B
A
and S dimensions (0.25-0.28). The optimal feature combination was MFCC + Hurst + 2-Rényi + Db. The model achieved a mean accuracy of 84.4%
a maximum accuracy of 91.0%
a sensitivity of 83.6%
a specificity of 85.1%
and an AUC of 0.89 with a 95% CI of 0.86-0.92.
Conclusion
2
A machine learning model integrating linear spectral features and multi-band nonlinear dynamic features can effectively distinguish normal voice from pathological voice. This approach demonstrates the feasibility of automatic pathological voice detection using the GRBAS G dimension as the supervisory label and may be useful for noninvasive clinical screening and objective voice evaluation.
中华医学会耳鼻咽喉头颈外科学分会嗓音学组 , 中华耳鼻咽喉头颈外科杂志编辑委员会咽喉组 . 嗓音功能评估专家共识(2024) [J ] . 中华耳鼻咽喉头颈外科杂志 , 2024 , 59 ( 12 ): 1267 - 1278 .
Patel RR , Awan SN , Barkmeier-Kraemer J , et al . Recommended protocols for instrumental assessment of voice: American Speech-Language-Hearing Association expert panel to develop a protocol for instrumental assessment of vocal function [J ] . American Journal of Speech-Language Pathology , 2018 , 27 ( 3 ): 887 - 905 .
Oates J . Auditory-perceptual evaluation of disordered voice quality: pros, cons and future directions [J ] . Folia Phoniatrica et Logopaedica , 2009 , 61 ( 1 ): 49 - 56 .
Takemoto N , Sanuki T , Kozaki A , et al . Reliability of auditory-perceptual voice evaluation: an investigation of GRBAS scale reproducibility among expert raters [J/OL ] . Journal of Voice , 2026 .
Özcebe E , Aydınlı FE , Tığrak TK , et al . Reliability and validity of the Turkish version of the Consensus Auditory-Perceptual Evaluation of Voice (CAPE-V) [J ] . Journal of Voice , 2019 , 33 ( 3 ): 382.e1 - 382.e10 .
刘阳 , 刘恒鑫 , 屈歌 , 等 . GRBAS和CAPE-V量表中文听感知评估一致性分析 [J ] . 听力学及言语疾病杂志 , 2025 , 33 ( 1 ): 23 - 28 .
De Bodt MS , Wuyts FL , Van de Heyning PH , et al . Test-retest study of the GRBAS scale: influence of experience and professional background on perceptual rating of voice quality [J ] . Journal of Voice , 1997 , 11 ( 1 ): 74 - 80 .
Sáenz-Lechón N , Godino-Llorente JI , Osma-Ruiz V , et al . Automatic assessment of voice quality according to the GRBAS scale [C ] . 2006 International Conference of the IEEE Engineering in Medicine and Biology Society . IEEE , 2006 , 2478 - 2481 .
Arias-Londoño JD , Godino-Llorente JI , Sáenz-Lechón N , et al . Automatic detection of pathological voices using complexity measures, noise parameters, and mel-cepstral coefficients [J ] . IEEE Transactions on Biomedical Engineering , 2011 , 58 ( 2 ): 370 - 379 .
Berteloot L , Sismono F , Maertens L , et al . AI-driven detection and classification of voice disorders using acoustic recordings [J/OL ] . Journal of Voice , 2026 .
Au YC , Yan N , Ng ML . Automatic assessment of voice quality using machine learning [J ] . Logopedics Phoniatrics Vocology , 2026 , 51 ( 3 ): 167 - 184 .
Davis SB , Mermelstein P . Comparison of parametric representations for monosyllabic word recognition in continuously spoken sentences [J ] . IEEE Transactions on Acoustics, Speech, and Signal Processing , 1980 , 28 ( 4 ): 357 - 366 .
Godino-Llorente JI , Gómez-Vilda P . Automatic detection of voice impairments by means of short-term cepstral parameters and neural network based detectors [J ] . IEEE Transactions on Biomedical Engineering , 2004 , 51 ( 2 ): 380 - 384 .
Awan SN , Roy N , Jetté ME , et al . Quantifying dysphonia severity using a spectral/cepstral-based acoustic index: comparisons with auditory-perceptual judgements from the CAPE-V [J ] . Clinical Linguistics & Phonetics , 2010 , 24 ( 9 ): 742 - 758 .
Yagnavajjula MK , Alku P , Rao KS , et al . Detection of neurogenic voice disorders using the Fisher vector representation of cepstral features [J ] . Journal of Voice , 2025 , 39 ( 3 ): 757 - 763 .
Maryn Y , Roy N , De Bodt M , et al . Acoustic measurement of overall voice quality: a meta-analysis [J ] . The Journal of the Acoustical Society of America , 2009 , 126 ( 5 ): 2619 - 2634 .
Baken RJ , Orlikoff RF . Clinical measurement of speech and voice [M ] . 2nd ed . San Diego : Singular Thomson Learning , 2000 . 130 - 137 , 190 - 213 .
Brockmann-Bauser M , Bohlender JE , Mehta DD . Acoustic perturbation measures improve with increasing vocal intensity in individuals with and without voice disorders [J ] . Journal of Voice , 2018 , 32 ( 2 ): 162 - 168 .
Ma EPM , Yiu EML . Suitability of acoustic perturbation measures in analysing periodic and nearly periodic voice signals [J ] . Folia Phoniatrica et Logopaedica , 2005 , 57 ( 1 ): 38 - 47 .
Little MA , McSharry PE , Roberts SJ , et al . Exploiting nonlinear recurrence and fractal scaling properties for voice disorder detection [J ] . BioMedical Engineering OnLine , 2007 , 6 : 23 - 23 .
Zhang XH , Hu WP . Pathological voice classification based on wavelet packet multiscale analysis [C ] . Proceedings of the 2018 International Conference on Algorithms, Computing and Artificial Intelligence . New York : ACM , 2018 , 1 - 6 .
Dalalana GJP , Guido RC , Honorato ES , et al . Application of wavelet analysis and paraconsistent feature extraction in the classification of voice pathologies [J/OL ] . Journal of Voice , 2025 .
庞宇峰 , 黄娟 , 徐蓓峥 , 等 . 病态嗓音的定量分析及人工神经网络识别 [J ] . 临床耳鼻咽喉头颈外科杂志 , 2017 , 31 ( 2 ): 100 - 102 .
Fang SH , Tsao Y , Hsiao MJ , et al . Detection of pathological voice using cepstrum vectors: a deep learning approach [J ] . Journal of Voice , 2019 , 33 ( 5 ): 634 - 641 .
Godino-Llorente JI , Gómez-Vilda P , Blanco-Velasco M . Dimensionality reduction of a pathological voice quality assessment system based on Gaussian mixture models and short-term cepstral parameters [J ] . IEEE Transactions on Biomedical Engineering , 2006 , 53 ( 10 ): 1943 - 1953 .
Maryn Y , Corthals P , Van Cauwenberge P , et al . Toward improved ecological validity in the acoustic measurement of overall voice quality: combining continuous speech and sustained vowels [J ] . Journal of Voice , 2010 , 24 ( 5 ): 540 - 555 .
Varma S , Simon R . Bias in error estimation when using cross-validation for model selection [J ] . BMC Bioinformatics , 2006 , 7 : 91 - 91 .
Cawley GC , Talbot NLC . On over-fitting in model selection and subsequent selection bias in performance evaluation [J ] . Journal of Machine Learning Research , 2010 , 11 : 2079 - 2107 .
Steyerberg EW , Jr Harrell FE . Prediction models need appropriate internal, internal-external, and external validation [J ] . Journal of Clinical Epidemiology , 2016 , 69 : 245 - 247 .
Van Calster B , McLernon DJ , van Smeden M , et al . Calibration: the Achilles heel of predictive analytics [J ] . BMC Medicine , 2019 , 17 : 230 - 230 .
0
浏览量
0
下载量
0
CSCD
关联资源
相关文章
相关作者
相关机构
京公网安备11010502052338